103 research outputs found

    Short, synthetic and selectively 13C-labeled RNA sequences for the NMR structure determination of protein-RNA complexes

    Get PDF
    We report an optimized synthesis of all canonical 2′-O-TOM protected ribonucleoside phosphoramidites and solid supports containing [13C5]-labeled ribose moieties, their sequence-specific introduction into very short RNA sequences and their use for the structure determination of two protein-RNA complexes. These specifically labeled sequences facilitate RNA resonance assignments and are essential to assign a high number of sugar-sugar and intermolecular NOEs, which ultimately improve the precision and accuracy of the resulting structures. This labeling strategy is particularly useful for the study of protein-RNA complexes with single-stranded RNA in solution, which is rapidly an increasingly relevant research area in biolog

    Short, synthetic and selectively 13C-labeled RNA sequences for the NMR structure determination of protein–RNA complexes

    Get PDF
    We report an optimized synthesis of all canonical 2′-O-TOM protected ribonucleoside phosphoramidites and solid supports containing [13C5]-labeled ribose moieties, their sequence-specific introduction into very short RNA sequences and their use for the structure determination of two protein–RNA complexes. These specifically labeled sequences facilitate RNA resonance assignments and are essential to assign a high number of sugar–sugar and intermolecular NOEs, which ultimately improve the precision and accuracy of the resulting structures. This labeling strategy is particularly useful for the study of protein–RNA complexes with single-stranded RNA in solution, which is rapidly an increasingly relevant research area in biology

    Imaging characteristics of intravascular spherical contrast agents for grating-based x-ray dark-field imaging - effects of concentrations, spherical sizes and applied voltage

    Get PDF
    This study investigates the x-ray scattering characteristics of microsphere particles in x-ray-grating-based interferometric imaging at different concentrations, bubble sizes and tube voltages (kV). Attenuation (ATI), dark-field (DFI) and phase-contrast (PCI) images were acquired. Signal-to-noise (SNR) and contrast-to-noise ratios with water (CNRw) and air as reference (CNRa) were determined. In all modalities, a linear relationship between SNR and microbubbles concentration, respectively, microsphere size was found. A significant gain of SNR was found when varying kV. SNR was significantly higher in DFI and PCI than ATI. The highest gain of SNR was shown at 60kV for all media in ATI and DFI, at 80kV for PCI. SNR for all media was significantly higher compared to air and was slightly lower compared to water. A linear relationship was found between CNRa, CNRw, concentration and size. With increasing concentration and decreasing size, CNRa and CNRw increased in DFI, but decreased in PCI. Best CNRa and CNRw was found at specific combination of kV and concentration/size. Highest average CNRa and CNRw was found for microspheres in ATI and PCI, for microbubbles in DFI. Microspheres are a promising contrast-media for grating-based-interferometry, if kV, microsphere size and concentration are appropriately combined

    Association between abdominal adiposity and subclinical measures of left-ventricular remodeling in diabetics, prediabetics and normal controls without history of cardiovascular disease as measured by magnetic resonance imaging: results from the KORA-FF4 Study

    Get PDF
    Objectives: Local, abdominal fat depots may be related to alterations in cardiac function and morphology due to a metabolic linkage. Thus, we aimed to determine their association with subtle cardiac changes and the potential interaction with hyperglycemic metabolic states. Methods: Subjects from the general population and without history of cardiovascular disease were drawn from the Cooperative Health Research in the Region of Augsburg FF4 cohort and underwent 3 T cardiac and body MRI. Measures of abdominal adiposity such as hepatic proton-density fat fraction [PDFFhepatic], subcutaneous (SAT) and visceral abdominal fat (VAT) as well as established cardiac left-ventricular (LV) measures including LV remodeling index (LVCI) were derived. Associations were determined using linear regression analysis based on standard deviation normalized predictors. Results: Among a total of 374 subjects (56.2 ± 9.1 years, 58% males), 49 subjects had diabetes, 99 subjects had prediabetes and 226 represented normal controls. Only subtle cardiac alterations were observed (e.g. LVCI: 1.13 ± 0.30). While SAT was not associated, increasing VAT and increasing PDFFhepatic were independently associated with increasing LVCI (β = 0.11 and 0.06, respectively), decreasing LV end-diastolic volume (β = − 6.70 and 3.23, respectively), and decreasing LV stroke volume (β = − 3.91 and − 2.20, respectively). Hyperglycemic state did not modify the associations between VAT or PDFF and LV measures (interaction term: all p ≥ 0.29). Conclusion: In a healthy population, VAT but also PDFFhepatic were associated with subclinical measures of LV remodeling without evidence for a modifying effect of hyperglycemic state

    Diagnosing and mapping pulmonary emphysema on X-ray projection images

    Get PDF
    To assess whether grating-based X-ray dark-field imaging can increase the sensitivity of X-ray projection images in the diagnosis of pulmonary emphysema and allow for a more accurate assessment of emphysema distribution. Lungs from three mice with pulmonary emphysema and three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Median signal intensities of transmission (T), dark-field (V) and a combined parameter (normalized scatter) were compared between emphysema and control group. To determine the diagnostic value of each parameter in differentiating between healthy and emphysematous lung tissue, a receiver-operating-characteristic (ROC) curve analysis was performed both on a per-pixel and a per-individual basis. Parametric maps of emphysema distribution were generated using transmission, dark-field and normalized scatter signal and correlated with histopathology. Transmission values relative to water were higher for emphysematous lungs than for control lungs (1.11 vs. 1.06, p<0.001). There was no difference in median dark-field signal intensities between both groups (0.66 vs. 0.66). Median normalized scatter was significantly lower in the emphysematous lungs compared to controls (4.9 vs. 10.8, p<0.001), and was the best parameter for differentiation of healthy vs. emphysematous lung tissue. In a per-pixel analysis, the area under the ROC curve (AUC) for the normalized scatter value was significantly higher than for transmission (0.86 vs. 0.78, p<0.001) and dark-field value (0.86 vs. 0.52, p<0.001) alone. Normalized scatter showed very high sensitivity for a wide range of specificity values (94% sensitivity at 75% specificity). Using the normalized scatter signal to display the regional distribution of emphysema provides color-coded parametric maps, which show the best correlation with histopathology. In a murine model, the complementary information provided by X-ray transmission and dark-field images adds incremental diagnostic value in detecting pulmonary emphysema and visualizing its regional distribution as compared to conventional X-ray projections

    Improved Detection of Foreign Bodies on Radiographs Using X-ray Dark-Field and Phase-Contrast Imaging

    Get PDF
    Purpose: The aim of this study was to investigate whether the detection of foreign bodies can be improved using dark-field and phase-contrast radiography compared with conventional (transmission) radiographs. Materials and Methods: Experiments were performed using ex vivo pig paws, which were prepared with differently sized foreign bodies of metal, wood, and glass (n = 10 each). Paws without foreign bodies served as controls (n = 30). All images were acquired using an experimental grating-based large object radiography system. Five blinded readers (second- to fourth-year radiology residents) were asked to assess the presence or absence of any foreign body. Sensitivity and specificity for the detection of metal, wood, glass, and any foreign body were calculated and compared using McNemar test and generalized linear mixed models. Results: Sensitivity for the detection of metal foreign bodies was 100% for all readers and image combinations. The sensitivity for the detection of wooden foreign bodies increased from 2% for transmission images to 78% when dark-field images were added (P < 0.0001). For glass foreign bodies, sensitivity increased from 84% for transmission images to 96% when adding phase-contrast images (P = 0.041). Sensitivity for the detection of any foreign body was 91% when transmission, dark-field, and phase-contrast images were viewed simultaneously, compared with 62% for transmission images alone (P < 0.0001). Specificity was 99% to 100% across all readers and radiography modalities. Conclusions: Adding dark-field images substantially improves the detection of wooden foreign bodies compared with the analysis of conventional (transmission) radiographs alone. Detection of glass foreign bodies was moderately improved when adding phase-contrast images

    Assessment of intraductal carcinoma in situ (DCIS) using grating-based X-ray phase-contrast CT at conventional X-ray sources: An experimental ex-vivo study

    Get PDF
    Background The extent of intraductal carcinoma in situ (DCIS) is commonly underestimated due to the discontinuous growth and lack of microcalcifications. Specimen radiography has been established to reduce the rate of re-excision. However, the predictive value for margin assessment with conventional specimen radiography for DCIS is low. In this study we assessed the potential of grating-based phase-contrast computed tomography (GBPC-CT) at conventional X-ray sources for specimen tomography of DCIS containing samples. Materials and methods GBPC-CT was performed on four ex-vivo breast specimens containing DCIS and invasive carcinoma of non-specific type. Phase-contrast and absorption-based datasets were manually matched with corresponding histological slices as the standard of reference. Results Matching of CT images and histology was successful. GBPC-CT showed an improved soft tissue contrast compared to absorption-based images revealing more histological details in the same sections. Non-calcifying DCIS exceeding the invasive tumor could be correlated to areas of dilated bright ducts around the tumor. Conclusions GBPC-CT imaging at conventional X-ray sources offers improved depiction quality for the imaging of breast tissue samples compared to absorption-based imaging, allows the identification of diagnostically relevant tissue details, and provides full three-dimensional assessment of sample margins

    Association of smoking and physical inactivity with MRI derived changes in cardiac function and structure in cardiovascular healthy subjects

    Get PDF
    We aimed to investigate the association of smoking and physical exercise on ventricular function and structure, determined by cardiac magnetic resonance imaging (CMR), in subjects without known cardiovascular diseases. A total of 381 participants (median age 57 years) of the Cooperative Health Research in the Region of Augsburg (KORA) FF4 cohort underwent CMR. The participants' smoking and sporting habits were measured by a questionnaire. Physical inactivity was associated with a reduction of left ventricular ejection fraction (LV-EF), stroke volume, early diastolic peak filling rate and peak ejection rate of the left ventricle as well as right ventricular stroke volume. LV-EF was reduced in subjects with almost no physical activity compared to subjects with regular physical activity (68.4%, 95%CI 66.8-70.1% vs. 70.8%, 95%CI 69.2-72.3%, p < 0,05). Smokers had lower right ventricular end-diastolic volumes (80.6 ml/m(2), 95%CI 76.7-84.5 ml/m(2);never-smokers: 85.5 ml/m(2), 95%CI 82.6-88.3 ml/m(2);p < 0.05) but higher extracellular volume fractions (ECV) and fibrosis volumes (34.3 ml, 95%CI 32.5-36.0 ml, vs. 31.0 ml, 95%CI 29.6-32.3 ml, p < 0.01). We conclude that asymptomatic individuals without known cardiovascular diseases show differences in cardiac function and structure depending on their physical activity and smoking habits. This underlines the importance of prevention and health education

    Ex Vivo Assessment of Coronary Atherosclerotic Plaque by Grating-Based Phase-Contrast Computed Tomography Correlation With Optical Coherence Tomography

    Get PDF
    Objectives: The aim of this study was to determine the diagnostic accuracy of grating-based phase-contrast computed tomography (gb-PCCT) to classify and quantify coronary vessel characteristics in comparison with optical coherence tomography (OCT) and histopathology in an ex vivo setting. Materials and Methods: After excision from 5 heart specimens, 15 human coronary arteries underwent gb-PCCT examination using an experimental imaging setup consisting of a rotating molybdenum anode x-ray tube, a Talbot-Lau grating interferometer, and a single photon counting detector. Subsequently, all vessels were imaged by OCT and histopathologically processed. Optical coherence tomography, gb-PCCT, and histopathology images were manually matched using anatomical landmarks. Optical coherence tomography and gb-PCCT were reviewed by 2 independent observers blinded to histopathology. Vessel, lumen, and plaque area were measured, and plaque characteristics (lipid rich, calcified, and fibrous) were determined for each section. Measures of diagnostic accuracy were derived, applying histopathology as the standard of reference. Results: Of a total of 286 assessed cross sections, 241 corresponding sections were included in the statistical analysis. Quantitative measures derived from gb-PCCT were significantly higher than from OCT (P = 0.85 for gb-PCCT and >= 0.61 for OCT, respectively). Results of Bland-Altman analysis demonstrated smaller mean differences between OCT and histopathology than for gb-PCCT and histopathology. Limits of agreement were narrower for gb-PCCT with regard to lumen area, for OCT with regard to plaque area, and were comparable with regard to vessel area. Based on histopathology, 228/241 (94.6%) sections were classified as fibrous, calcified, or lipid rich. The diagnostic accuracy of gb-PCCT was excellent for the detection of all plaque components (sensitivity, >= 0.95;specificity, >= 0.94), whereas the results for OCT showed sensitivities of >= 0.73 and specificities of >= 0.66. Conclusions: In this ex vivo setting, gb-PCCT provides excellent results in the assessment of coronary atherosclerotic plaque characteristics and vessel dimensions in comparison to OCT and histopathology. Thus, the technique may serve as adjunct nondestructive modality for advanced plaque characterization in an experimental setting
    • …
    corecore